Prefabricated house structure
External wall W1

- Horizontal cladding
- Laths 45x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- Vapor barrier
- Laths 45x45mm, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W2

- Vertical cladding
- Laths 45x45mm Horizontal (air gap), calibrated timber c/c 600
- Laths 28x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- Vapor barrier
- Laths 45x45mm, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W3

- Horizontal cladding
- Laths 45x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- Windproof gypsum
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- Vapor barrier
- Laths 45x45mm, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W4

- Vertical cladding
- Laths 45x45mm Horizontal (air gap), calibrated timber c/c 600
- Laths 28x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- Windproof gypsum
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- Vapor barrier
- Laths 45x45mm, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W5

- Horizontal cladding
- Laths 45x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- OSB boards 12mm
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- Vapor barrier
- Laths 45x45mm, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W6

- Vertical cladding
- Laths 45x45mm Horizontal (air gap), calibrated timber c/c 600
- Laths 28x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- OSB boards 12mm
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- Vapor barrier
- Laths 45x45mm, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W7

- Horizontal cladding
- Laths 45x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- OSB boards 12mm
- Vapor barrier
- Laths 45x45mm, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W8

- Vertical cladding
- Laths 45x45mm Horizontal (air gap), calibrated timber c/c 600
- Laths 28x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- OSB boards 12mm
- Vapor barrier
- Laths 45x45mm, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W9

- Horizontal cladding
- Laths 45x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- Windproof gypsum
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- OSB boards 12mm
- Vapor barrier
- Laths 45x45mm, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W10

- Vertical cladding
- Laths 45x45mm Horizontal (air gap), calibrated timber c/c 600
- Laths 28x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- Windproof gypsum
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- OSB boards 12mm
- Vapor barrier
- Laths 45x45mm, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W11

- Horizontal cladding
- Laths 45x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- OSB boards 12mm
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- OSB boards 12mm
- Vapor barrier
- Laths 45x45mm, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W12

- Vertical cladding
- Laths 45x45mm Horizontal (air gap), calibrated timber c/c 600
- Laths 28x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- OSB boards 12mm
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- OSB boards 12mm
- Vapor barrier
- Laths 45x45mm, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W2

- Horizontal cladding
- Laths 45x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- Windproof gypsum
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- Vapor barrier
- Laths 45x45mm, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W3

- Vertical cladding
- Laths 45x45mm Horizontal (air gap), calibrated timber c/c 600
- Laths 28x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- OSB boards 12mm
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- Vapor barrier
- Laths 45x45mm, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W4

- Horizontal cladding
- Laths 45x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- OSB boards 12mm
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- Vapor barrier
- Laths 45x45mm, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W5

- Vertical cladding
- Laths 45x45mm Horizontal (air gap), calibrated timber c/c 600
- Laths 28x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- Vapor barrier
- Laths 45x45mm, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W6

- Horizontal cladding
- Laths 45x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- Windproof gypsum
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- OSB Boards 12mm
- Vapor barrier
- Laths 45x45mm, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W7

- Vertical cladding
- Laths 45x45mm Horizontal (air gap), calibrated timber c/c 600
- Laths 28x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- Windproof gypsum
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- OSB Boards 12mm
- Vapor barrier
- Laths 45x45mm Horizontal, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W8

- Vertical cladding
- Laths 45x45mm Horizontal (air gap), calibrated timber c/c 600
- Laths 28x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- Laths 45x45mm Horizontal (extra frame), calibrated timber c/c 600
- Insulation 50mm
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- Vapor barrier
- Laths 45x45mm Vertical, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W9

- Vertical cladding
- Laths 45x45mm Horizontal (air gap), calibrated timber c/c 600
- Laths 28x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- Windproof gypsum
- Laths 45x45mm Horizontal (extra frame), calibrated timber c/c 600
- Insulation 50mm
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- OSB Boards 12mm
- Vapor barrier
- Laths 45x45mm Vertical, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W10

- Vertical cladding
- Laths 45x45mm Horizontal (air gap), calibrated timber c/c 600
- Laths 28x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- Windproof gypsum
- Laths 45x45mm Horizontal (extra frame), calibrated timber c/c 600
- Insulation 50mm
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- OSB Boards 12mm
- Vapor barrier
- Laths 45x45mm Horizontal, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W11

- Horizontal cladding
- Laths 45x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- Windproof gypsum
- Laths 45x45mm Horizontal (extra frame), calibrated timber c/c 600
- Insulation 50mm
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- OSB Boards 12mm
- Vapor barrier
- Laths 45x45mm Vertical, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W12

- Vertical cladding
- Laths 45x45mm Horizontal (air gap), calibrated timber c/c 600
- Laths 28x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- Laths 45x45mm Horizontal (extra frame), calibrated timber c/c 600
- Insulation 50mm
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- OSB Boards 12mm
- Vapor barrier
- Laths 45x45mm Vertical, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W12

- Vertical cladding
- Laths 45x45mm Horizontal (air gap), calibrated timber c/c 600
- Laths 28x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- Laths 45x45mm Horizontal (extra frame), calibrated timber c/c 600
- Insulation 50mm
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- OSB Boards 12mm
- Vapor barrier
- Laths 45x45mm Vertical, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W13

- Vertical cladding
- Laths 45x45mm Horizontal (air gap), calibrated timber c/c 600
- Laths 28x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- Laths 45x45mm Horizontal (extra frame), calibrated timber c/c 600
- Insulation 50mm
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- Vapor barrier
- Laths 45x45mm Vertical, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W14

- Horizontal cladding
- Laths 45x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- Windproof gypsum
- Laths 45x45mm Horizontal (extra frame), calibrated timber c/c 600
- Insulation 50mm
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- Vapor barrier
- Laths 45x45mm Vertical, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
External wall W15

- Horizontal cladding
- Laths 45x45mm Vertical (air gap), calibrated timber c/c 600
- Diffusion membrane
- Windproof gypsum
- Laths 45x45mm Horizontal (extra frame), calibrated timber c/c 600
- Insulation 50mm
- Timber frame 45x195mm, calibrated timber c/c 600, Class C24
- Insulation 200mm
- Vapor barrier
- Laths 45x45mm Horizontal, calibrated timber
- Insulation 50mm
- Gypsum boards 12.5mm
Internal wall W1

- Gypsum boards 12.5mm
- Timber frame 45x95mm, calibrated timber c/c 600, Class C24
- Insulation 100mm
- Gypsum boards 12.5mm
Internal wall W2

- Gypsum boards 12.5mm
OSB Boards 12mm
- Timber frame 45x95mm, calibrated timber c/c 600, Class C24
- Insulation 100mm
- OSB Boards 12mm
- Gypsum boards 12.5mm
Ceiling 1F

- Forestia plates – 22mm
- Timber frame 45x245mm, calibrated timber c/c 600, Class C24
- Insulation 250mm
- Laths 45x45mm Horizontal (air gap), calibrated timber c/c 600
- Insulation 50mm
- Gypsum plates 12.5mm
- Laths 45x45mm Vertical (for insulation), calibrated timber c/c 600
Ceiling 2F

- Forestia plates – 22mm
- STEICO joist frame
- Insulation
- Laths 45x45mm Horizontal (air gap), calibrated timber c/c 600
- Insulation 50mm
- Gypsum plates 12.5mm
Roof 1R

- Metal sheets
- Laths 25x100mm Horizontal, calibrated timber c/c 600
Laths 45x45mm Vertical (Air gap), calibrated timber c/c 600 - Windproof film
- Timber frame 45x245mm, calibrated timber c/c 600, Class C24
- Insulation 250mm
- Laths 45x45mm Horizontal, calibrated timber c/c 600
- Insulation 50mm
- Gypsum boards 12.5mm
- Gutters
- Fascia boards
- Soffit boards
Roof 2R

- EPDM Firestone RubberGard membrane
- Plate Durelis Populair TG4 24mm
- Laths 45x45mm Vertical (Air gap), calibrated timber c/c 600
- Windproof film
- Timber frame 45x245mm, calibrated timber c/c 600, Class C24
- Insulation 250mm
- Laths 45x45mm Horizontal, calibrated timber c/c 600
- Insulation 50mm
- Gypsum boards 12.5mm
- Gutters
- Fascia boards
- Soffit boards
Roof 3R

- Metal sheets
- Laths 25x100mm Horizontal, calibrated timber c/c 600
Laths 45x45mm Vertical (Air gap), calibrated timber c/c 600 - Windproof film
- STEICO joist frame
- Insulation
- Laths 45x45mm Horizontal, calibrated timber c/c 600
- Insulation 50mm
- Gypsum boards 12.5mm
- Gutters
- Fascia boards
- Soffit boards
Roof 4R

- EPDM Firestone RubberGard membrane
- Plate Durelis Populair TG4 24mm
- Laths 45x45mm Vertical (Air gap), calibrated timber c/c 600
- Windproof film
- STEICO joist frame
- Insulation
- Laths 45x45mm Horizontal, calibrated timber c/c 600
- Insulation 50mm
- Gypsum boards 12.5mm
- Gutters
- Fascia boards
- Soffit boards